Apr 15, 2023 Leave a message

Compressor Complies With Regulations

The installation of compressors should comply with relevant local laws and regulations, and strictly follow the following regulations:
1. The compressor should be lifted using lifting equipment with a load-bearing capacity greater than the weight of the unit, and the lifting speed and acceleration should be limited within the allowable range.
2. Try to install the compressor in a cool, clean, and well ventilated place to ensure that the air sucked in by the compressor is clean and has a minimum moisture content.
3. The air sucked in by the compressor is not allowed to contain flammable or corrosive gases, in order to avoid potential explosion or internal corrosion.
4. For air-cooled machines, it is best to have an exhaust fan or air duct to guide the hot air out of the room, avoiding the circulation of hot air to the air inlet.
5. The discharge of compressor sewage and waste oil should comply with the regulations of the local environmental protection department.
6. This machine uses a three-phase AC power supply of 380V and 50Hz. The power supply line of the guide compressor must match its power and be equipped with safety devices such as air switches and fuses. To ensure the reliability and safety of electrical equipment, reliable grounding is necessary.
Debugging operation
1. New machine debugging must be carried out by debugging personnel designated or recognized by the company [12];
2. Before starting the machine, it is necessary to confirm that there is no one inside the unit and check for any leftover items or tools. Close the door of the unit; When starting the machine, the personnel around the unit should be notified to pay attention to safety;
3. During trial operation, strictly check the running direction of the compressor. If reverse rotation is found, immediately shut down the machine, cut off the power supply, switch any two of the three phase lines back on before restarting, otherwise the compressor will be damaged (attention must be paid to every factory power maintenance!)
4. The compressor cannot operate at a discharge pressure higher than the specified on the nameplate, otherwise it may cause the motor to overload and burn out;
5. When the compressor is under remote control and the machine may start at any time, a warning board should be hung to remind;
6. When the compressor malfunctions or there are unsafe factors present, do not forcefully start it. At this time, cut off the power supply and mark it prominently.